mirror of
https://github.com/metrostroi-repo/MetrostroiAddon.git
synced 2026-05-04 00:52:33 +00:00
Implemented rechargeable battery and imitation of control circuit's current. Randomized initial battery voltage and relays trigger level
This commit is contained in:
@@ -131,6 +131,8 @@ function ENT:Initialize()
|
||||
Pos = Vector(-177, -66, -50), Radius = 20,
|
||||
},
|
||||
}
|
||||
self.BattCurrent = 0
|
||||
self.eds_eq = 0
|
||||
|
||||
-- Cross connections in train wires
|
||||
self.TrainWireInverts = {
|
||||
@@ -228,6 +230,9 @@ end
|
||||
|
||||
function ENT:TrainSpawnerUpdate()
|
||||
self:SetNW2Bool("Custom",self.CustomSettings)
|
||||
self.Battery:TriggerInput("CarType",1)
|
||||
self.Battery:TriggerInput("InitialVoltage",math.random(62,75))
|
||||
self.Battery:TriggerInput("Dischargeable",self:GetNW2Bool("BattCharge"))
|
||||
local num = self.WagonNumber
|
||||
math.randomseed(num+817171)
|
||||
if self.CustomSettings then
|
||||
@@ -357,23 +362,9 @@ function ENT:Think()
|
||||
self:SetPackedRatio("BCPressure", Pneumatic.BrakeCylinderPressure/6.0)
|
||||
|
||||
----------------------------------*****************************--------------------------------
|
||||
--10th wire voltage readout imitation depending on the BPSNs and EKK state, not on the wagon battery switch state
|
||||
local hvcounter = 0
|
||||
local hvcar = nil
|
||||
local vdrop = 1.125*(#self.WagonList)
|
||||
for k,v in ipairs(self.WagonList) do
|
||||
if v.PowerSupply.X2_2 > 0 and v.A24.Value > 0 then
|
||||
hvcounter = hvcounter + 1
|
||||
hvcar = hvcar or v
|
||||
vdrop = vdrop - 1.125
|
||||
else
|
||||
vdrop = vdrop - ((v.A56.Value == 0 and 0.4 or (v.VB.Value == 0 and 0.4 or 0)) + (v.LK4.Value == 0 and 0.725 or 0))
|
||||
end
|
||||
end
|
||||
local PCV_o = hvcounter > 0 and math.Clamp(76+(hvcar.Electric.Aux750V - 600)*8/375, 76, 84) - vdrop or self.WagonList[1].Battery.Voltage
|
||||
--imitating converter overload protection only when control circuits are energized and at least one PC on the train is off; pretty useless btw (but fun)
|
||||
local pcloadratio = #self.WagonList/(hvcounter > 0 and hvcounter or 0.5)
|
||||
local _A = 25*(6 - 6/(5.01)) --assuming one PC on 6 cars can work for 25 secs while the cars' CCs are energized
|
||||
local pcloadratio = #self.WagonList/(self.Battery.hvcounter > 0 and self.Battery.hvcounter or 0.5)
|
||||
local _A = 90*(6 - 6/(5.01)) --assuming one PC on 6 cars can work for 90 secs while the cars' CCs are energized
|
||||
if pcloadratio > 1 and pcloadratio <= #self.WagonList and self.LK4.Value > 0 and self.PowerSupply.X2_2 > 0 and not self.pcrlxtimer then
|
||||
self.pcprotimer = self.pcprotimer or CurTime()
|
||||
--hyperbolic function of PC operating time depending on load coeff
|
||||
@@ -394,8 +385,8 @@ function ENT:Think()
|
||||
self.PowerSupply:TriggerInput("3x2",self.pcrlxtimer and 1 or 0) --BPSN overheat protection in case of RZP button is being pressed constantly
|
||||
----------------------------------*****************************--------------------------------
|
||||
|
||||
self:SetPackedRatio("BatteryVoltage",Panel["V1"]*PCV_o/150.0)
|
||||
self:SetPackedRatio("BatteryCurrent",Panel["V1"]*math.Clamp((self.Battery.Voltage-75)*0.01,-0.01,1))
|
||||
self:SetPackedRatio("BatteryVoltage",(self.eds_eq)/150.0)
|
||||
self:SetPackedRatio("BatteryCurrent",self.BattCurrent/1000)
|
||||
self:SetPackedRatio("EnginesCurrent", 0.5 + 0.5*(self.Electric.I24/500.0))
|
||||
|
||||
self:SetPackedBool("Compressor",Pneumatic.Compressor > 0)
|
||||
|
||||
Reference in New Issue
Block a user