Implemented rechargeable battery and imitation of control circuit's current. Randomized initial battery voltage and relays trigger level

This commit is contained in:
Moon Horse
2023-05-02 02:22:30 +03:00
parent d17cb74904
commit 0027160c2d
15 changed files with 156 additions and 73 deletions

View File

@@ -223,6 +223,8 @@ function ENT:Initialize()
self.PassengerDoor = false
self.OtsekDoor1 = false
self.OtsekDoor2 = false
self.BattCurrent = 0
self.eds_eq = 0
self.Lamps = {
broken = {},
@@ -381,6 +383,15 @@ function ENT:TrainSpawnerUpdate()
--
local num = self.WagonNumber
self:SetNW2Bool("Custom",self.CustomSettings)
self.Battery:TriggerInput("CarType",1)
self.Battery:TriggerInput("InitialVoltage",math.random(62,75))
self.Battery:TriggerInput("Dischargeable",self:GetNW2Bool("BattCharge"))
local ccc = 0
self.ComputerCar = false
for k,v in ipairs(self.WagonList) do
if v.AR63 and v.ComputerCar then ccc = ccc + 1; break end
end
if ccc == 0 then self.ComputerCar = true end
math.randomseed(num+817171)
if self.CustomSettings then
--{"Type","Spawner.717.Type","List",{"Spawner.717.Type.717","Spawner.717.Type.7175"}},
@@ -677,24 +688,9 @@ function ENT:Think()
self:SetPackedRatio("EnginesCurrent", 0.5 + 0.5*(self.Electric.I24/500.0))
----------------------------------*****************************--------------------------------
--10th wire voltage readout imitation depending on the BPSNs and EKK state, not on the wagon battery switch state
-- PC — power converter; CC — control circuits
local hvcounter = 0
local hvcar = nil
local vdrop = 1.125*(#self.WagonList)
for k,v in ipairs(self.WagonList) do
if v.PowerSupply.X2_2 > 0 and v.A24.Value > 0 then
hvcounter = hvcounter + 1
hvcar = hvcar or v
vdrop = vdrop - 1.125
else
vdrop = vdrop - ((v.A56.Value == 0 and 0.4 or (v.VB.Value == 0 and 0.4 or 0)) + (v.LK4.Value == 0 and 0.725 or 0))
end
end
local PCV_o = hvcounter > 0 and math.Clamp(76+(hvcar.Electric.Aux750V - 600)*8/375, 76, 84) - vdrop or self.WagonList[1].Battery.Voltage
--imitating converter overload protection only when control circuits are energized and at least one PC on the train is off; pretty useless btw (but fun)
local pcloadratio = #self.WagonList/(hvcounter > 0 and hvcounter or 0.5)
local _A = 25*(6 - 6/(5.01)) --assuming one PC on 6 cars can work for 25 secs while the cars' CCs are energized
local pcloadratio = #self.WagonList/(self.Battery.hvcounter > 0 and self.Battery.hvcounter or 0.5)
local _A = 90*(6 - 6/(5.01)) --assuming one PC on 6 cars can work for 90 secs while the cars' CCs are energized
if pcloadratio > 1 and pcloadratio <= #self.WagonList and self.LK4.Value > 0 and self.PowerSupply.X2_2 > 0 and not self.pcrlxtimer then
self.pcprotimer = self.pcprotimer or CurTime()
--hyperbolic function of PC operating time depending on load coeff
@@ -715,7 +711,7 @@ function ENT:Think()
self.PowerSupply:TriggerInput("3x2",self.pcrlxtimer and 1 or 0) --BPSN overheat protection in case of RZP button is being pressed constantly
----------------------------------*****************************--------------------------------
self:SetPackedRatio("BatteryVoltage",Panel["V1"]*PCV_o/150.0)
self:SetPackedRatio("BatteryVoltage",(self.eds_eq)/150.0)
self:SetPackedBool("Compressor",Pneumatic.Compressor > 0)
self:SetPackedBool("Buzzer",Panel.Ring >= 1)