1
0
mirror of https://github.com/metrostroi-repo/MetrostroiAddon.git synced 2026-05-02 00:42:29 +00:00

Update init.lua

This commit is contained in:
BlueSnooty
2022-01-28 22:44:04 +03:00
committed by GitHub
parent db950c2f75
commit 615ea526b9

View File

@@ -357,12 +357,12 @@ function ENT:Think()
self:SetPackedRatio("BCPressure", Pneumatic.BrakeCylinderPressure/6.0)
----------------------------------*****************************--------------------------------
--10th wire voltage readout imitation depending on the BPSNs and EKK state, not on the wagon battery switch state
local hvcounter = 0
--10th wire voltage readout imitation depending on the BPSNs and EKK state, not on the wagon battery switch state
local hvcounter = 0
local hvcar = nil
local vdrop = 1.125*(#self.WagonList)
for k,v in ipairs(self.WagonList) do
if v.PowerSupply.X2_2 > 0 and v.A24.Value > 0 then
if v.PowerSupply.X2_2 > 0 and v.A24.Value > 0 then
hvcounter = hvcounter + 1
hvcar = hvcar or v
vdrop = vdrop - 1.125
@@ -373,18 +373,16 @@ function ENT:Think()
local PCV_o = hvcounter > 0 and math.Clamp(76+(hvcar.Electric.Aux750V - 600)*8/375, 76, 84) - vdrop or self.WagonList[1].Battery.Voltage
--imitating converter overload protection only when control circuits are energized and at least one PC on the train is off; pretty useless btw (but fun)
local pcloadratio = #self.WagonList/(hvcounter > 0 and hvcounter or 0.5)
--local _a = 25*(#self.WagonList - #self.WagonList/(#self.WagonList-1))
local _A = 25*(6 - 6/(5.01)) --assuming one PC on 6 cars can work for 25 secs while the cars' CCs are energized
local _A = 25*(6 - 6/(5.01)) --assuming one PC on 6 cars can work for 25 secs while the cars' CCs are energized
if pcloadratio > 1 and pcloadratio <= #self.WagonList and self.LK4.Value > 0 and self.PowerSupply.X2_2 > 0 and not self.pcrlxtimer then
self.pcprotimer = self.pcprotimer or CurTime()
--if CurTime() - self.pcprotimer > _a/(pcloadratio + _a/25 - #self.WagonList) + self._pcdiff then --hyperbolic function of PC operating time depending on load coeff
--hyperbolic function of PC operating time depending on load coeff
if CurTime() - self.pcprotimer > _A/(pcloadratio - 6/5.01) then
--self.RZP:TriggerInput("Close",1)
self.pcrlxtimer = CurTime()
end
else
if self.pcrlxtimer then
if CurTime() - self.pcrlxtimer < 30 then --30 seconds relaxation time before PC overload protecion can be reset
if CurTime() - self.pcrlxtimer < 30 then --30 seconds relaxation time before PC overload protecion can be reset
self.RZP:TriggerInput("Close",1)
else
self.pcrlxtimer = nil
@@ -393,7 +391,7 @@ function ENT:Think()
self.pcprotimer = nil
end
end
self.PowerSupply:TriggerInput("3x2",self.pcrlxtimer and 1 or 0) --BPSN overheat protection in case of RZP button is being pressed constantly
self.PowerSupply:TriggerInput("3x2",self.pcrlxtimer and 1 or 0) --BPSN overheat protection in case of RZP button is being pressed constantly
----------------------------------*****************************--------------------------------
self:SetPackedRatio("BatteryVoltage",Panel["V1"]*PCV_o/150.0)